80V 70A Forklift Battery Charger CZB5C-D SCR Line Frequency Charger for 405-560Ah Batteries
Product Details
| Output Voltage: | 48V | Output Current: | 100A |
|---|---|---|---|
| Application: | Electric Forklift | Technology: | Silicon-Controlled Rectifier |
| Model: | CZB5C-D80V/70A | Type: | Forklift Battery Charger |
| Output Voltage: | 80V DC (40 X 2V Cells) | Output Current: | 70A Maximum |
| Battery Capacity: | 405-560Ah (8.5h Rate) | Input Voltage: | 3-phase 380V AC (220V/415V Input Currents Published) |
| Input Power: | 8.8 KVA | Dimensions: | 526 X 360 X 882 Mm |
| Net Weight: | 87 Kg | Technology: | SCR Phase-angle Control, Line-frequency Transformer |
| Charge Characteristic: | Wa Taper With Timed Equalising Finish | Cooling: | Thermostatic Forced Air |
| Protection: | Open Circuit, Reverse Connection, Overload, Short Circuit, Over-temperature | Warranty: | 12 Months |
| Application: | 80V Four-wheel Counterbalance Trucks, Reach Trucks And Terminal Tractors With 405-560Ah Lead Acid Packs, In Ports, Steel Service Centres And Distribution Centres Running Two Shifts. | ||
| Highlight |
80V 70A Forklift Charger,SCR Line Frequency Charger,405-560Ah Battery Charger |
||
Product Description
Quick answer: CZB5C-D80V/70A is a three-phase SCR charger giving 70A at 80V for 405-560Ah packs on counterbalance trucks, reach trucks and terminal tractors in ports and steel service centres. 8.8 kVA input, 526 x 360 x 882 mm, 87 kg, CE and ISO9001, 15 days delivery.
Seventy amps is the rating that appears when an 80V fleet grows up. The packs get bigger, the trucks get heavier, and the 65A unit that was fine for a 450Ah battery starts finishing late. The CZB5C-D80V/70A covers the 405-560Ah band without stepping up to the 80A cabinet, which keeps the input draw and the price in a different bracket. It is the same transformer-fed SCR design, with the current set where the larger pack needs it.
SCR stands for Silicon Controlled Rectifier, a four-layer PNPN thyristor. It blocks current in both directions until a gate pulse lets it conduct, and then it stays latched until the current falls to zero at the end of a half cycle. In a charger it does the job a dimmer does for a lamp, except that it is switching 70A and it has a mains transformer in front of it.
The sequence inside the cabinet is short enough to describe in one sentence: three-phase mains enters a 50Hz transformer that steps the voltage down to the level the pack needs, a thyristor bridge rectifies and regulates it, and a closed-loop controller trims the firing angle so the output current holds at the set value while the pack voltage climbs. There is no high-frequency switching stage and no firmware-defined charge profile to go out of date.
Two consequences follow. The current limit is set by copper and silicon rather than by software, so a stalled fan or a shorted connector is absorbed by the hardware instead of being computed. And every power part is a catalogue item - thyristor, fuse, contactor, fan, relay - which is why a CZB5C built years ago is still repairable in a workshop that has never seen a wiring diagram.
- It survives the supply. Panel plants, ports and foundries have voltage dips and phase imbalance. A transformer front end rides through them; a switching supply protects itself and stops.
- It is repaired in-house. Thyristors, contactors, fuses, fans and control relays are off-the-shelf parts. No proprietary board, no factory return, no three-week air freight.
- It is forgiving of heat. There is no dense electronics stack sitting above the heat source. The transformer is the heat source, and it is designed to run hot.
- It can be re-tapped. A different pack voltage or capacity is a tap change and a setting, not a new charger.
- It gives decades of service. Winding insulation and a fan motor are the wear items, and both are replaceable on site.
- The trade-off is honest. More weight, more footprint, and a few points less efficiency than a high-frequency design. For a battery room that runs every day, that is a fair exchange.
| Parameter | Value |
|---|---|
| Model | CZB5C-D80V/70A |
| Charging technology | SCR phase-angle control, line-frequency transformer |
| Input voltage | 3-phase 380V AC (220V / 415V input currents published) |
| Input current @220V / @380V / @415V | 23.0 / 13.3 / 12.2 A |
| Input power | 8.8 kVA |
| Output voltage | 80V DC (40 x 2V cells) |
| Output current | 70A maximum |
| Battery capacity | 405-560Ah at the 8.5h discharge rate |
| Charge characteristic | Wa taper with timed equalising finish |
| Dimensions | 526 x 360 x 882 mm |
| Net weight | 87 kg |
| Cooling | Thermostatic forced air |
| Protection | Open circuit, reverse connection, overload, short circuit, over-temperature |
| Warranty | 12 months |
A 480Ah pack discharged to 20% has 384Ah to replace. At 70A the bulk stage takes about five and a half hours, and the taper brings the total to roughly eight hours with the equalising finish included. On a 405Ah pack the same current is 0.17C, still acceptable but close to the upper limit for daily cycling; on a 560Ah pack it is 0.125C, which is where a long-life battery wants to live. The charger does not decide this - the pack does - but the 70A rating covers the whole band without a compromise at either end.
The difference between 65A and 70A looks small on paper and is not small in a battery room. On a 560Ah pack, 70A is 0.125C - the gentle end of the range - while 65A would be 0.116C and would leave the pack short of a full charge by the end of a short turnaround. The CZB5C-D80V/70A is sized for sites where the trucks come back with more than 80% depth of discharge and the next shift cannot wait.
- The truck is brought to the bay, the key switch is turned off and the battery connector is made. Reverse connection is detected before the contactor closes.
- The unit runs its automatic battery detection, applies the delayed start, then soft-starts into the pack. Nothing slams the plates with full current at t=0.
- Current holds at the set value while voltage climbs through the gassing level. The double closed loop tracks voltage and current together and corrects the firing angle continuously.
- Current tapers along the Wa curve, the standard taper characteristic: current falls as the pack comes up, finishing at a low float-level current rather than a hard cut.
- The equalising stage holds the finish for its set period, bringing the cells back to a common specific gravity before the charger shuts down.
- The finish data is written to memory, one of the last 30 recharges a technician can read back when a pack starts to underperform.
The same cabinet family covers 48V and 80V packs, from 55A to 120A. If this model is not the exact fit, the table shows the alternatives on the same transformer platform.
| Model | Power (kVA) | Input current 220/380/415V (A) | Output current (A) | Battery V | Battery Ah (8.5h) | Dimensions (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| D48V/55A | 4.1 | 10.8 / 6.3 / 5.7 | 55 | 48 | 320-440 | 466x361x785 | 62 |
| D48V/65A | 4.9 | 12.8 / 7.4 / 6.8 | 65 | 48 | 375-520 | 466x361x785 | 65 |
| D48V/80A | 6.0 | 15.7 / 9.1 / 8.3 | 80 | 48 | 465-640 | 466x361x785 | 68 |
| D48V/100A | 7.5 | 19.7 / 11.4 / 10.4 | 100 | 48 | 580-800 | 526x360x882 | 86 |
| D48V/120A | 9.0 | 23.6 / 13.7 / 12.5 | 120 | 48 | 700-960 | 526x360x882 | 95 |
| D80V/65A | 8.1 | 21.3 / 12.3 / 11.3 | 65 | 80 | 375-520 | 526x360x882 | 87 |
| D80V/70A | 8.8 | 23.0 / 13.3 / 12.2 | 70 | 80 | 405-560 | 526x360x882 | 87 |
| D80V/80A | 10.0 | 26.2 / 15.2 / 13.9 | 80 | 80 | 465-640 | 526x360x882 | 89 |
| D80V/100A | 12.5 | 32.8 / 19.0 / 17.4 | 100 | 80 | 580-800 | 526x360x882 | 95 |
| D80V/120A | 15.0 | 39.4 / 22.8 / 20.9 | 120 | 80 | 700-960 | 526x360x882 | 107 |
Battery capacity is quoted at the 8.5h discharge rate. Special specifications are tailor designed on request: connector type, cable length, input voltage and paint colour can all be set at order.
- Supply. A dedicated three-phase feed with an isolation and protection device rated for the input current in the table above.
- Cable. Keep the DC run to the truck short and correctly sized. 70A through an undersized cable turns into heat, voltage drop and a slow charge.
- Air. Free air on the fan side of the cabinet, and ventilation for the pack itself. Charging a flooded pack in a sealed room is a hydrogen problem, not a charger problem.
- Position. Floor-standing, level, away from direct water spray. Castors are available where the bay is shared between trucks.
- Connector. Tell us the plug you standardise on. DIN 160A, Anderson and fixed bolt terminations are all supplied to order.
- Weekly: confirm the fan runs and the intake is not blanketed in dust. Overheat faults in hot bays are almost always airflow, not electronics.
- Monthly: check the finish voltage against the pack specification and read back the last recharges from memory.
- Per pack service: run the equalising charge as scheduled, and use the desulphation function on packs that have been left standing.
- Spares to hold: thyristors, fuses, a fan and a contactor. That is the whole wear list, and it fits in a shoebox.
Silicon Controlled Rectifier, a thyristor. The charger steps the mains down through a transformer and regulates with a phase-controlled thyristor bridge. It is the classic heavy-duty charger topology, and it is still the most repairable one.
No. The CZB5C is a lead-acid Wa taper charger. Lithium packs need a CC/CV profile with cell balancing communication; for those we supply the CZC7 and ESCH lithium series. Using the wrong topology on a lithium pack is a safety issue, not a warranty issue.
Three-phase 220V, 380V and 415V are the standard options, with the input current for each published in the table. Single-phase input is available on the smaller E-series models, not on this cabinet.
15 days after order confirmation and deposit, with a supply capacity of 5000 pieces per month across the range.
The charger is packed in a plywood case with a moisture barrier, fumigation free, and can be shipped EXW, FOB or CIF. To quote accurately, send four lines: pack voltage and cell count, capacity in Ah, the number of trucks charged per shift, and the connector type you use.
Application: 80V four-wheel counterbalance trucks, reach trucks and terminal tractors with 405-560Ah lead acid packs, in ports, steel service centres and distribution centres running two shifts.
1. Basic Product Information
Model: CZB5C Series (including key specification D48V/100A)
Phase: Three Phases
Input Type: Three-phase AC (3/PE) input power
2. Product Introduction
3. Application Scenarios
4. Product Specification Table
5. Product Features
Precise Control Technology: Adopts a voltage and current double closed-loop framework combined with PID control technology. It can dynamically track the battery state in real time and automatically adjust charging parameters (such as charging current and voltage) to ensure a stable and efficient charging process and avoid battery damage caused by mismatched parameters.
Comprehensive Data Monitoring: Equipped with a nixie tube display, which can clearly show core parameters during charging—including battery voltage, charging current, charged capacity, and charging duration. It can also display charging curve codes and fault codes, facilitating users to grasp the charging progress and equipment status in real time. It is matched with high-intensity LED lights to intuitively indicate the operating status of the charger (such as "standby", "charging", "charging completed", "fault", etc.), making operation convenient.
Intelligent Protection Functions:
Has automatic detection and delayed soft-start functions to avoid large current impact on the battery and charger at startup, extending the service life of the equipment.
Built-in temperature compensation function. During charging, it can automatically adjust the critical voltage of gas evolution according to the ambient temperature to prevent undercharging at low temperatures and overcharging at high temperatures.
Supports data recording of 30 charging completions, facilitating users to trace the charging history and troubleshoot equipment problems.
Multiple Safety Protections:
Circuit Protection: Has open circuit, reverse connection, over load, and short circuit breakdown protection and alarm functions. When an abnormality occurs, it immediately cuts off the charging circuit and alarms to ensure the safety of equipment and personnel.
Component Protection: Sets overheat fault protection and alarm functions for transformers and modules to avoid damage to core components due to overheating.
Battery Maintenance Functions:
Supports equalization charge, which can balance the capacity of each single battery in the battery pack, solve the problem of overall capacity decline caused by "battery imbalance", and maintain the consistency of the battery pack.
Has an automatic initial charge function, which is suitable for the first charging needs of new batteries to ensure complete activation of new batteries.
Built-in desulfuration charge function, which can remove sulfides on the battery plates, repair slightly sulfated batteries, restore battery capacity, and extend battery service life.
6. Our Service
Product Highlights
CZB5C-D80V/70A is a three-phase SCR charger giving 70A at 80V for 405-560Ah packs on counterbalance trucks, reach trucks and terminal tractors in ports and steel service centres. 8.8 kVA input, 526 x 360 x 882 mm, 87 kg, CE and ISO9001, 15 days delivery.
80v 500AH Screw connection traction Battery Customized For MHE Forklift
80v 500AH Screw connection traction Battery Customized For MHE Forklift Type Forklift Battery Application Electric Forklift Truck Standard DIN standard Width of cell 198mm Technology Tubular Positive Plates Model 80v 500Ah Cell Quantities 40 cells Cell Voltage 2V Connection Type Flexible/Soft ...
Heli CPD20 Forklift Battery 48V 600Ah For Electric Counterbalance Forklift
Product description This battery features small size, light weight, large capacity and long service life. It is designed for exceptional performance and high reliability, and is compatible with over 100 forklift brands and more than 800 models. Our batteries are suitable for various types of ...
24v 280AH Screw connection traction Battery Customized For Heli Forklift
24v 280AH Screw connection traction Battery Customized For Heli Forklift Product Introduction Industrial traction lead-acid battery with stable 1500+ deep discharge cycles, good anti-corrosion & anti-aging performance for heavy continuous operation. REMA or Anderson connectors can be selected freely ...
Forklift Battery Basket Vent Plug
Size M Pallet Jack Battery Vent Plug Filling Caps Durable CE Certification Vent Filling Caps Application Forklift batteries / traction batteries Mode LK-CAP-5 Total Length 74.75mm Size M Product Catalog Model Total Length Vent Filling Caps LK-CAP-4 63mm Vent Filling Caps LK-CAP-5 74.75mm Vent ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.