80V 80A Forklift Battery Charger CZB5C-D Transformer SCR Charger for 465-640Ah Traction Packs
Product Details
| Model: | CZB5C 48V/100A | Type: | Forklift Lithium Ion Battery Chargers |
|---|---|---|---|
| Output Voltage: | 48V | Output Current: | 100A |
| Brand: | LAKER | Technology: | Silicon-Controlled Rectifier |
| Battery Parameter: | 48V 580-800Ah | Size: | 526×360×882 Mm |
| Model: | CZB5C-D80V/80A | Type: | Forklift Battery Charger |
| Output Voltage: | 80V DC (40 X 2V Cells) | Output Current: | 80A Maximum |
| Battery Capacity: | 465-640Ah (8.5h Rate) | Input Voltage: | 3-phase 380V AC (220V/415V Input Currents Published) |
| Input Power: | 10.0 KVA | Dimensions: | 526 X 360 X 882 Mm |
| Net Weight: | 89 Kg | Technology: | SCR Phase-angle Control, Line-frequency Transformer |
| Charge Characteristic: | Wa Taper With Timed Equalising Finish | Cooling: | Thermostatic Forced Air |
| Protection: | Open Circuit, Reverse Connection, Overload, Short Circuit, Over-temperature | Warranty: | 12 Months |
| Application: | 80V Heavy Counterbalance Trucks, Container Handlers And Large Reach Trucks With 465-640Ah Lead Acid Packs, In Steel Plants, Ports And Multi-shift Logistics Operations. | ||
| Highlight |
80V 80A Forklift Charger,CZB5C-D Transformer Charger,465-640Ah Traction Charger |
||
Product Description
Quick answer: Silicon controlled rectification lets this LAKER 48V 100A lithium ion charger serve forklift packs without stressing cells, and the same unit also handles lead acid batteries. Multi chemistry tolerance simplifies fleet standardisation.
The 80A 80V combination is where an SCR charger stops being convenient and starts being necessary. A 640Ah pack at 80A is 0.125C, and at that size the charger is on for most of a shift, through heat, dust and the voltage sag of a loaded plant supply. A transformer-fed unit with a thyristor bridge does not mind any of it. The CZB5C-D80V/80A is that unit: 10kVA on the input, 80A on the DC side, and a wear list that fits in a shoebox.
SCR stands for Silicon Controlled Rectifier, a four-layer PNPN thyristor. It blocks current in both directions until a gate pulse lets it conduct, and then it stays latched until the current falls to zero at the end of a half cycle. In a charger it does the job a dimmer does for a lamp, except that it is switching 80A and it has a mains transformer in front of it.
The sequence inside the cabinet is short enough to describe in one sentence: three-phase mains enters a 50Hz transformer that steps the voltage down to the level the pack needs, a thyristor bridge rectifies and regulates it, and a closed-loop controller trims the firing angle so the output current holds at the set value while the pack voltage climbs. There is no high-frequency switching stage and no firmware-defined charge profile to go out of date.
Two consequences follow. The current limit is set by copper and silicon rather than by software, so a stalled fan or a shorted connector is absorbed by the hardware instead of being computed. And every power part is a catalogue item - thyristor, fuse, contactor, fan, relay - which is why a CZB5C built years ago is still repairable in a workshop that has never seen a wiring diagram.
- It survives the supply. Panel plants, ports and foundries have voltage dips and phase imbalance. A transformer front end rides through them; a switching supply protects itself and stops.
- It is repaired in-house. Thyristors, contactors, fuses, fans and control relays are off-the-shelf parts. No proprietary board, no factory return, no three-week air freight.
- It is forgiving of heat. There is no dense electronics stack sitting above the heat source. The transformer is the heat source, and it is designed to run hot.
- It can be re-tapped. A different pack voltage or capacity is a tap change and a setting, not a new charger.
- It gives decades of service. Winding insulation and a fan motor are the wear items, and both are replaceable on site.
- The trade-off is honest. More weight, more footprint, and a few points less efficiency than a high-frequency design. For a battery room that runs every day, that is a fair exchange.
| Parameter | Value |
|---|---|
| Model | CZB5C-D80V/80A |
| Charging technology | SCR phase-angle control, line-frequency transformer |
| Input voltage | 3-phase 380V AC (220V / 415V input currents published) |
| Input current @220V / @380V / @415V | 26.2 / 15.2 / 13.9 A |
| Input power | 10.0 kVA |
| Output voltage | 80V DC (40 x 2V cells) |
| Output current | 80A maximum |
| Battery capacity | 465-640Ah at the 8.5h discharge rate |
| Charge characteristic | Wa taper with timed equalising finish |
| Dimensions | 526 x 360 x 882 mm |
| Net weight | 89 kg |
| Cooling | Thermostatic forced air |
| Protection | Open circuit, reverse connection, overload, short circuit, over-temperature |
| Warranty | 12 months |
A 550Ah 80V pack at 20% depth needs 440Ah back. At 80A the bulk stage is about five and a half hours, and the Wa taper plus equalising finish lands the full charge in the eight-hour window. On the 465Ah pack the rate is 0.17C - the top of the daily-cycling range - and on the 640Ah pack it is 0.125C. The 80A rating is the widest single-current cover in the CZB5C family for 80V fleets, which is why it is the model most often specified for mixed truck sizes.
High-frequency chargers are smaller and lighter, and on a clean single-shift site they are the right answer. The CZB5C-D80V/80A is for the other site: the one where the supply dips when a crane starts, where the battery room is next to a shot-blast cabinet, and where the maintenance team repairs what it can with parts from the local electrical wholesaler. The transformer and the thyristor bridge absorb that environment in a way a dense switching board does not.
- The truck is brought to the bay, the key switch is turned off and the battery connector is made. Reverse connection is detected before the contactor closes.
- The unit runs its automatic battery detection, applies the delayed start, then soft-starts into the pack. Nothing slams the plates with full current at t=0.
- Current holds at the set value while voltage climbs through the gassing level. The double closed loop tracks voltage and current together and corrects the firing angle continuously.
- Current tapers along the Wa curve, the standard taper characteristic: current falls as the pack comes up, finishing at a low float-level current rather than a hard cut.
- The equalising stage holds the finish for its set period, bringing the cells back to a common specific gravity before the charger shuts down.
- The finish data is written to memory, one of the last 30 recharges a technician can read back when a pack starts to underperform.
The same cabinet family covers 48V and 80V packs, from 55A to 120A. If this model is not the exact fit, the table shows the alternatives on the same transformer platform.
| Model | Power (kVA) | Input current 220/380/415V (A) | Output current (A) | Battery V | Battery Ah (8.5h) | Dimensions (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| D48V/55A | 4.1 | 10.8 / 6.3 / 5.7 | 55 | 48 | 320-440 | 466x361x785 | 62 |
| D48V/65A | 4.9 | 12.8 / 7.4 / 6.8 | 65 | 48 | 375-520 | 466x361x785 | 65 |
| D48V/80A | 6.0 | 15.7 / 9.1 / 8.3 | 80 | 48 | 465-640 | 466x361x785 | 68 |
| D48V/100A | 7.5 | 19.7 / 11.4 / 10.4 | 100 | 48 | 580-800 | 526x360x882 | 86 |
| D48V/120A | 9.0 | 23.6 / 13.7 / 12.5 | 120 | 48 | 700-960 | 526x360x882 | 95 |
| D80V/65A | 8.1 | 21.3 / 12.3 / 11.3 | 65 | 80 | 375-520 | 526x360x882 | 87 |
| D80V/70A | 8.8 | 23.0 / 13.3 / 12.2 | 70 | 80 | 405-560 | 526x360x882 | 87 |
| D80V/80A | 10.0 | 26.2 / 15.2 / 13.9 | 80 | 80 | 465-640 | 526x360x882 | 89 |
| D80V/100A | 12.5 | 32.8 / 19.0 / 17.4 | 100 | 80 | 580-800 | 526x360x882 | 95 |
| D80V/120A | 15.0 | 39.4 / 22.8 / 20.9 | 120 | 80 | 700-960 | 526x360x882 | 107 |
Battery capacity is quoted at the 8.5h discharge rate. Special specifications are tailor designed on request: connector type, cable length, input voltage and paint colour can all be set at order.
- Supply. A dedicated three-phase feed with an isolation and protection device rated for the input current in the table above.
- Cable. Keep the DC run to the truck short and correctly sized. 80A through an undersized cable turns into heat, voltage drop and a slow charge.
- Air. Free air on the fan side of the cabinet, and ventilation for the pack itself. Charging a flooded pack in a sealed room is a hydrogen problem, not a charger problem.
- Position. Floor-standing, level, away from direct water spray. Castors are available where the bay is shared between trucks.
- Connector. Tell us the plug you standardise on. DIN 160A, Anderson and fixed bolt terminations are all supplied to order.
- Weekly: confirm the fan runs and the intake is not blanketed in dust. Overheat faults in hot bays are almost always airflow, not electronics.
- Monthly: check the finish voltage against the pack specification and read back the last recharges from memory.
- Per pack service: run the equalising charge as scheduled, and use the desulphation function on packs that have been left standing.
- Spares to hold: thyristors, fuses, a fan and a contactor. That is the whole wear list, and it fits in a shoebox.
Silicon Controlled Rectifier, a thyristor. The charger steps the mains down through a transformer and regulates with a phase-controlled thyristor bridge. It is the classic heavy-duty charger topology, and it is still the most repairable one.
No. The CZB5C is a lead-acid Wa taper charger. Lithium packs need a CC/CV profile with cell balancing communication; for those we supply the CZC7 and ESCH lithium series. Using the wrong topology on a lithium pack is a safety issue, not a warranty issue.
Three-phase 220V, 380V and 415V are the standard options, with the input current for each published in the table. Single-phase input is available on the smaller E-series models, not on this cabinet.
15 days after order confirmation and deposit, with a supply capacity of 5000 pieces per month across the range.
The charger is packed in a plywood case with a moisture barrier, fumigation free, and can be shipped EXW, FOB or CIF. To quote accurately, send four lines: pack voltage and cell count, capacity in Ah, the number of trucks charged per shift, and the connector type you use.
Application: 80V heavy counterbalance trucks, container handlers and large reach trucks with 465-640Ah lead acid packs, in steel plants, ports and multi-shift logistics operations.
100A 48V Forklift Lithium Ion Battery Chargers Silicon Controlled Rectifier
Introduction:
Forklift Lithium Ion Battery Chargers can meet the charging needs of various types of lead-acid batteries and can be used for normal charging and maintenance charging of electric vehicles, such as forklift, electric flat cars, electric stackers and tourist cars. With the optimized Wa curves, with the application of microprocessor control technology and intelligent dynamic regulating charging technology, so the charging can penetrate into inside of battery plate to reach a complete charging and during the charging process, keep the battery in the state of micro scale bubbling to reduce the evaporating of electrolytic obviously to raise the charging efficiency and battery working life. The product has the feature of perfect function, smart outlook, new man-machine interface, high power factor, energy saving with complete range of type and specification,desktop and vertical stand cubics; it is an idea choice for wide range of customers.
Product Catalogs:
- Three-phase AC(3/PE) input power voltage.
Product Features:
- The Voltage and current double closed-loop framework is applied in the PID control technology. This device can achieve dynamic tracking and automatic adjustment of charge parameters.
- Nixie tube would display charger parameters such as battery voltage, charge current, capacity and recharged time. It could als show the code of charging curve and fault. High-intensity LED lamp would indicate running state of this charging unit.
- Functions of automatic detection, delaying and soft-start, Function of temperature compensation. The voltage of tipping point of gas emission would change with the temperature.
- Tis device could also record data as the end of recharge for 30 times.
- Protection and alarm functions of open crcuit, reverse connection, over load and short circuit breakdown.
- Protection and alarm functions of overheat fault of transformer and module.
- Equalization charge could ensure caacity consistency of battery packs, function of automatic initial charge, function of desulfuration charge.
Our Service
We will provide the best service for user both during selling and after-sales. Welcome the customer to choose our products. Please, inform us the type and specification of battery, we can recommend the most suitable charger for you.
Product Highlights
Silicon controlled rectification lets this LAKER 48V 100A lithium ion charger serve forklift packs without stressing cells, and the same unit also handles lead acid batteries. Multi chemistry tolerance simplifies fleet standardisation.
80v 500AH Screw connection traction Battery Customized For MHE Forklift
80v 500AH Screw connection traction Battery Customized For MHE Forklift Type Forklift Battery Application Electric Forklift Truck Standard DIN standard Width of cell 198mm Technology Tubular Positive Plates Model 80v 500Ah Cell Quantities 40 cells Cell Voltage 2V Connection Type Flexible/Soft ...
Heli CPD20 Forklift Battery 48V 600Ah For Electric Counterbalance Forklift
Product description This battery features small size, light weight, large capacity and long service life. It is designed for exceptional performance and high reliability, and is compatible with over 100 forklift brands and more than 800 models. Our batteries are suitable for various types of ...
24v 280AH Screw connection traction Battery Customized For Heli Forklift
24v 280AH Screw connection traction Battery Customized For Heli Forklift Product Introduction Industrial traction lead-acid battery with stable 1500+ deep discharge cycles, good anti-corrosion & anti-aging performance for heavy continuous operation. REMA or Anderson connectors can be selected freely ...
Forklift Battery Basket Vent Plug
Size M Pallet Jack Battery Vent Plug Filling Caps Durable CE Certification Vent Filling Caps Application Forklift batteries / traction batteries Mode LK-CAP-5 Total Length 74.75mm Size M Product Catalog Model Total Length Vent Filling Caps LK-CAP-4 63mm Vent Filling Caps LK-CAP-5 74.75mm Vent ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.